[Home]
[Full version]
Chemists probe combustion process
Jan 04 ,General Science
Chemists at the U.S. Department of Energy's Brookhaven National Laboratory, working with colleagues at Stony Brook University, have developed a unique experimental technique to measure the flow of energy inside a molecule in the process of breaking apart. The chemists' experiments provide a critical test of theories used in computer models of combustion, which are used, for instance, by combustion engineers to design more fuel-efficient and less polluting machines.
"With a trustworthy computer model of combustion, engineers can design improved engines or fuel blends without needing to build and test so many different versions," said Brookhaven chemist Gregory Hall, the principal researcher for this experiment. "The database of chemical reactions needed for such a computer program is too big to be filled in strictly with measured numbers, and we have to rely on chemical rate theory to calculate much of this database. Our experiments are important for showing how far we should trust these calculations."
The Chemical Physics Research Program in DOE's Office of Basic Energy Sciences funded the research, which is due to be published online today in the Journal of Chemical Physics.
The chemists used an experimental technique called "sliced ion imaging" to analyze the energy flow during the fragmentation of ketene, a small molecule that acts as a stand-in for more complicated fuels in these benchmark experiments. When excited with a laser, ketene breaks apart into carbon monoxide and methylene fragments, pushing away from each other with a speed that depends on the rotational and vibrational energies of the two fragment molecules. Some of the carbon monoxide fragments are then ionized (an electron is removed) by a second laser, and the ions are accelerated toward a detector screen, where each ion shows up as a flash of light, observed with a video camera. Depending on how fast and in what direction the carbon monoxide fragments were traveling when they were born, the ions will hit a different spot on the ion-imaging detector. By analyzing the images obtained by accumulating the signals from about half a million molecules, the Brookhaven scientists can determine how energy is shared between the two fragments. They have found agreement with the predictions of a chemical rate theory called variational transition state theory, refuting some earlier work that had raised questions about this theory.
"The 'slicing' is a key new feature of this method," Hall said. "By using a fast shutter on the ion detector, we can wait until the middle of the ion cloud reaches the detector before we pulse the shutter on and off again. This way, we are looking only at the molecules that originally were moving parallel to the plane of the detector. That makes the images sharper and more accurate."
Source: Brookhaven National Laboratory
Related stories:
Scientists take the sharpest image ever made with light
(PhysOrg.com) -- A team of scientists from the Technische Universität Dresden (Germany) and the ESRF in Grenoble (France) has produced the image of an object at the highest resolution ever achieved with X-ray light. A 100-nanometre gold particle fixed on a substrate was reconstructed with 5 nanometre resolution. Contrary to other techniques, X-ray imaging works also in real-life environments like chemical processing or in the presence of high magnetic fields. The team reports its findings in the newest issue of
Phys. Rev. Lett. dated 5 September 2008 (published online 29 August 2008).
A first in integrated nanowire sensor circuitry
Scientists at the U.S. Department of Energy's Lawrence Berkeley National Laboratory and the University of California at Berkeley have created the world's first all-integrated sensor circuit based on nanowire arrays, combining light sensors and electronics made of different crystalline materials. Their method can be used to reproduce numerous such devices with high uniformity.
New detector uses nanotubes to sense deadly gases
Using carbon nanotubes, MIT chemical engineers have built the most sensitive electronic detector yet for sensing deadly gases such as the nerve agent sarin.
Prototype Terahertz Imager Promises Biochem Advances
Researchers at the National Institute of Standards and Technology have demonstrated a new imaging system that detects naturally occurring terahertz radiation with unprecedented sensitivity and resolution. The technology may become a new tool chemical and biochemical analyses ranging from early tumor detection to rapid and precise identification of chemical hazards for homeland security instruments.
Crime scene investigations: Gunshot residue analysis on a single gunpowder particle
Scientists in Texas are reporting development of an highly dependable, rapid, and inexpensive new method for identifying the presence of gunshot residue (GSR). The test fills a GSR-detection gap that results from wider use of “green” — lead free — ammunition.
Crafty Tricks for Finding Moon Water
Bright gray, crater-pocked mountains taller than Mount McKinley. Abyssal craters that could swallow several Grand Canyons whole.
Biosensing nanodevice to revolutionize health screenings
One day soon a biosensing nanodevice developed by Arizona State University researcher Wayne Frasch may eliminate long lines at airport security checkpoints and revolutionize health screenings for diseases like anthrax, cancer and antibiotic resistant Staphylococcus aureus (MRSA).
Modified electron microscope identifies atoms
A new electron microscope recently installed in Cornell's Duffield Hall is enabling scientists for the first time to form images that uniquely identify individual atoms in a crystal and see how those atoms bond to one another. And in living color.
[Home]
[Full version]