Lamivudine is an effective antiviral agent for treatment of patients with chronic hepatitis B and advanced liver diseases. However, long-term lamivudine monotherapy leads to the emergence of lamivudine-resistant hepatitis B virus (HBV) mutants in some patients chronically infected with HBV. Sensitive methods for early detection of lamivudine-resistant mutants will help physicians make clinical decisions in treating patients with HBV infection.
To date, many assays have been used for detection of lamivudine-resistant mutants in patients with Hepatitis B. Differences in sensitivity, specificity, cost, and time required, exist in these methods. Real-time PCR is able to quantitatively detect a small portion of resistant mutants in HBV populations and ligase detection reaction (LDR) is a newly developed method for detection of low abundant mutants in the background of wild-type HBV. However, there are no studies which have compared the clinical performance of the two methods.
A research article to be published on January 7 in the World Journal of Gastroenterology (volume 14, issue 1) addresses this question. It compared LDR and real-time PCR for detection of low abundant YMDD mutations in mixed plasmids and serum samples from 52 lamivudine treated patients. Time required and reagent cost for both assays were evaluated. The research was conducted carefully by an experienced team of investigators.
The article suggested both methods are sensitive and inexpensive for detection of YMDD mutation; but LDR is more sensitive than real-time PCR. The results obtained with both methods were completely concordant in all serum samples. LDR was able to detect as low as 0.01% (100 copies/mL) of YIDD plasmid, while real-time PCR only detected 0.1% (1000 copies/mL) of YIDD plasmid in the background of YMDD plasmid. In addition, the cost of LDR is slightly lower than that of real-time PCR.
However, real-time PCR is much more rapid and requires less manual work than LDR. The total assay time for LDR and real-time PCR was 4.5 and 2.5 h, respectively. Another advantage of the real-time PCR method is it is able to calculate the ratio of mutants to total virus in samples. This will be useful in clinical studies on the dynamics of resistant mutants during lamivudine therapy.
Source: World Journal of Gastroenterology
Related stories:
Real-time space radiation forecasting in place
A new method for predicting the approach and intensity of hazardous particles from extreme solar events that would threaten astronauts and technology in space is now in place. Researchers are using this initial forecasting phase to qualify the method for operational use in space exploration activities.
Strange Space Weather over Africa
Something strange is happening in the atmosphere above Africa and researchers have converged on Addis Ababa, Ethiopia, to discuss the phenomenon. The Africa Space Weather Workshop kicked off Nov. 12th with nearly 100 scientists and students in attendance.
Killer electrons in space are now less mysterious
A rare, timely conjunction of ground-based instrumentation and a dozen satellites has helped scientists better understand how electrons in space can turn into ‘killers’. ESA’s Cluster constellation has contributed crucially to the finding.
SuitSat: listen to a disembodied spacesuit circling Earth
One of the strangest satellites in the history of the space age is about to go into orbit. Launch date: Feb. 3rd. That's when astronauts onboard the International Space Station (ISS) will hurl an empty spacesuit overboard. The spacesuit
is the satellite -- "SuitSat" for short.
Channel-Hopping on Mobile Phones
A new technology for mobile communication networks allows cell phone users to watch TV as they would at home. The Mobile TV Streaming system from Siemens makes it possible to change channels instantly. Other streaming solutions can take up to 15 seconds for this. In addition there are no long downloading times, since the data reaches the phone virtually in realtime.
5.1 Surround Sound for FM HD Radio at NAB 2005
Fraunhofer IIS, Telos, Omnia, Axia, Broadcast Electronics and Bose participate in world-premiere live demon-stration of non-matrixed 5.1 Surround Sound for FM HD Radio.
Fraunhofer Institute for Integrated Circuits IIS and its partners join to present at the 2005 NAB show a first live demonstration. The end-to-end demonstration will involve the complete HD Radio broadcasting chain comprising the studio, on-air broadcasting and automotive digital radio receivers. The original multi-channel material will be mixed in discrete 5.1 surround at the Axia booth and then passed over a wireless link to the Telos / Omnia booth to be encoded for surround by Fraunhofer IIS Spatial Audio software. As a next step the encoded material is processed for FM transmission and broadcast on an HD Radio channel using a Broadcast Electronics HD Radio Exciter.
NTT DoCoMo Achieves 1Gbps Packet Transmission in 4G
According to JCN Network, NTT DoCoMo announced December 17 that it succeeded in achieving 1Gbps in downlink packet data transmission in a laboratory experiment using forth-generation (4G) mobile communication radio access equipment on August 20, 2004.
New IP Phones from Siemens for Communication over IP
With optiPoint 420, the Siemens Communications Group has launched a new telephone family for the business customer segment. The optiPoint 420 series comprises IP phones that offer users major new advantages when communicating via the Internet Protocol. Integrated IP applications permit a high degree of flexibility and mobility for every workplace. For example, the devices in this telephone family are especially suited for desk sharing or for employees who move from workplace to workplace thanks to the automatic transfer and display of screen entries.