The technology can improve the portability while reducing the size, complexity, and cost of many sensing and diagnostics systems that use spectrometers. The technology has appeared in Applied Optics, Optics Express and Optics Letters and was presented as an invited talk at the IEEE Lasers and Electro-Optics Society Annual Meeting 2005.
Conventional spectrometers have multiple parts -- a narrow slit, a lens (to guide light), a grating (to separate wavelengths), a second lens and a detector (to detect the power at different wavelengths). The Georgia Tech team's goal was to combine all these pieces into two parts, a volume hologram (formed in an inexpensive piece of polymer) and a detector, to create a compact, efficient and inexpensive spectrometer that could be used for multiple spectroscopy and sensing applications.
"This technology is very useful for low-end spectrometers, but at the same time, there are many applications that require high-end spectrometers. This technology could convert a portion of a complex, high-end system into a much more versatile and light system," said Ali Adibi, head of the project and an associate professor in the School of Electrical and Computer Engineering.
Because of its light weight and relative insensitivity to optical alignment, the new design helps create more versatile and portable spectrometers for several applications where portability had been difficult. For instance, the technology would make hand held devices possible for carbon monoxide detection or on-the-spot blood analysis and other biomedical applications.
One of the key advantages to the new spectrometer is its insensitivity to alignment. Spectrometers are very sensitive to the direction and wavelength of light and several of their parts are devoted to keeping the light correctly directed.
But the Georgia Tech team was able to incorporate those necessary alignments along with the focusing functions into a volume hologram. This hologram is recorded by the interference pattern of two beams in a piece of photopolymer.
"There were lots of challenges because the light we need to analyze is diffuse in nature," Adibi said.
Conventional spectrometers work the best under collimated light (i.e. light moving in only one direction). However, the optical signal needed for practical sensing applications is diffuse. This problem is solved in conventional spectrometers by blocking light in all but one direction using a slit and a lens, but this also results in considerable power loss and lower efficiency.
"By choosing the appropriate hologram, we have no collimating hardware in our system. We have further demonstrated the capability of improving the throughput by using more complex holograms, which are recorded similar to less complex holograms, in our spectrometer without adding to the actual complexity of the system," Adibi added.
The Georgia Tech team has a prototype for a lower-end spectrometer comparable to those currently on the market but for a considerably lower cost, Adibi said. Their research will now focus on developing more complex systems by using specially designed volume holograms to improve the efficiency -- and thus the sensitivity -- of our spectrometers, Adibi added.
Source: Georgia Institute of Technology
Related stories:
Scientists search for answers from the carbon in the clouds
An aerosol mass spectrometer developed by chemists from Aerodyne Research Inc. and Boston College is giving scientists who study airborne particles the technology they need to examine the life cycles of atmospheric aerosols – such as soot – and their impact on issues ranging from climate change to public health.
CU-Boulder scientists ready for MESSENGER Mission flyby of Mercury
NASA will point a power-packed $8.7 million University of Colorado at Boulder space instrument at some of the last unexplored terrain in the inner solar system when the MESSENGER spacecraft whips within 125 miles of Mercury's surface Jan. 14 at a mind-boggling 141,000 miles per hour.
Two-photon absorbing molecules fabricate polymer features just 65 nanometers wide
Producing three-dimensional polymer line structures as small as 65 nanometers wide just became easier with new two-photon absorbing molecules that are sensitive to laser light at short wavelengths, allowing researchers to create them without highly sophisticated fabrication methods.
Experiments help explain mysterious 'floppy' space molecule
A laboratory method developed for making and analyzing cold, concentrated samples of a mysterious "floppy" molecule thought to be abundant only in outer space has revealed new data that help explain the molecule's properties.
New Sub-Millimetre Light in the Desert
The Atacama Pathfinder Experiment (APEX) project has just passed another major milestone by successfully commissioning its new technology 12-m telescope, located on the 5100m high Chajnantor plateau in the Atacama Desert (Chile). The APEX telescope, designed to work at sub-millimetre wavelengths, in the 0.2 to 1.5 mm range, has just performed its first scientific observations. This new front-line facility will provide access to the "Cold Universe" with unprecedented sensitivity and image quality.
New NIST Method Improves Accuracy of Spectrometers
Measurements of the intensity of light at different wavelengths can be made more accurately now, thanks to a new, simple method for correcting common instrument errors. The new method, developed by researchers at the National Institute of Standards and Technology (NIST), will benefit fields such as color measurement, lighting development, remote sensing, biotechnology and astronomy.
Argonne-designed instruments vital in RHIC discovery
Argonne researchers played a significant role in research that led to the surprising
finding of a possible ideal liquid instead of the expected quark-gluon plasma at Brookhaven National Laboratory's
Relativistic Heavy-Ion Collider (RHIC).
On April 18, each of the four major experiments at RHIC released white papers summarizing the first four years of RHIC operation and their findings from high-energy collisions of gold nuclei. At the incredibly high temperatures and pressures created in the collisions, physicists expected to create "
quark-gluon plasma" - a gaseous state of matter thought to have existed in the first few microseconds after the Big Bang. Instead, the matter created inside the detectors behaved like a liquid - a completely unexpected result.
Crystals in Nanofocus
Max Planck Scientists strike new paths in nanoanalysis and data storage with infrared light
Scientists of the Nano-Photonics Group at the Max Planck Institute of Biochemistry have
developed a new infrared-optical nanotechnology based on the excitation of lattice vibrations in polar crystals (phonons). The technology, called "phonon photonics", opens up entirely new applications of infrared light: non-destructive chemical and structural analysis of crystals at a resolution better than 1/10000 mm, infrared data storage providing storage densities better than DVD, nanoscopic infrared-sensors or waveguides and switches for the development of future infrared-optical supercomputers. The physicists in Martinsried present their initial studies on silicon carbide crystals in the latest issue of NATURE MATERIALS (Nature Materials, September 2004, published online 1 August 2004).